Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Chinese Acupuncture & Moxibustion ; (12): 463-468, 2023.
Article in Chinese | WPRIM | ID: wpr-980745

ABSTRACT

The difficulties such as how to accurately locate acupoints and safely insert needles are presented in acupuncture robot. The puncture robot with high technological similarity to acupuncture robot is getting mature, and a large number of human trials and animal experiments have been conducted for the development of puncture robot. Through comparing the similarities and differences between puncture robot and acupuncture robot in the aspects of through-skin puncture, needle insertion and needle removal, the valuable technology of puncture robot is analyzed for the development of acupuncture robot, and the crucial direction of technology migration is determined. ①Integrating the mechanical feedback and medical imaging technology and utilizing the multi-modal perception to achieve the safety of acupuncture operation. ②Emphasizing the integration of the existing designs of chest puncture robot to realize the acupuncture operation with inhalation and exhalation involved. ③Focusing on the development of relevant technology of automatic needle removal through conducting the actual scenario of treatment with acupuncture robot in patients under non-anaesthetic condition.


Subject(s)
Animals , Humans , Robotics , Feasibility Studies , Acupuncture Therapy , Punctures , Acupuncture , Needles
2.
Chinese Acupuncture & Moxibustion ; (12): 199-202, 2022.
Article in Chinese | WPRIM | ID: wpr-927359

ABSTRACT

Under the background of artificial intelligence, the internationalization of acupuncture and moxibustion has braced an important opportunity. Intelligent medical equipment for acupuncture and moxibustion has entered from the laboratory into the clinic. However, the current research focuses on optimizing acupuncture treatment technology rather than innovating acupuncture theory. Internationally, the westernization of traditional acupuncture and the dilution of its characteristics are worrying. It is urgent to promote the China-led international standards of acupuncture and moxibustion and the patent protection of traditional acupuncture and moxibustion. Intelligent medical equipment will play the role of media, and promote the internationalization of traditional acupuncture and moxibustion with standardized and highly-integrated intelligent medical equipment for acupuncture and moxibustion, and integrate modern scientific and technological achievements. It is a feasible way for the internationalization of acupuncture and moxibustion.


Subject(s)
Acupuncture Therapy , Artificial Intelligence , China , Moxibustion , Research , Robotics
3.
Frontiers of Medicine ; (4): 404-416, 2020.
Article in English | WPRIM | ID: wpr-827856

ABSTRACT

A number of developed countries are rapidly turning into super-aged societies. Consequently, the demand for reduced surgical invasiveness and enhanced efficiency in the medical field has increased due to the need to reduce the physical burden on older patients and shorten their recovery period. Intelligent surgical robot systems offer high precision, high safety, and reduced invasiveness. This paper presents a review of current intelligent surgical robot systems. The history of robots and three types of intelligent surgical robots are discussed. The problems with current surgical robot systems are then analyzed. Several aspects that should be considered in designing new surgical systems are discussed in detail. The paper ends with a summary of the work and a discussion of future prospects for surgical robot development.

4.
Chinese Journal of Tissue Engineering Research ; (53): 3797-3802, 2020.
Article in Chinese | WPRIM | ID: wpr-847458

ABSTRACT

BACKGROUND: In the elderly patients with degenerative lumbar spinal stenosis, bilateral nerve root canal stenosis commonly shows only one side of symptoms. There is still controversy about whether or not decompression is needed on the side without symptoms or with less symptoms and how to operate. OBJECTIVE: To explore the safety and efficacy of robot-assisted unilateral-decompression using minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) technique by investigating a series of cases with the radiographic bilateral lumbar canal stenosis presenting with unilateral symptoms and by comparing clinical decompression effect and imaging changes before and after operation. METHODS: Cases with radiographic bilateral lumbar canal stenosis presenting with unilateral symptoms subjected to unilateral decompression on the affected side, interbody fusion and bilateral fixation after robot-assisted MIS-TLIF in the same treatment group were retrospectively analyzed. Operation time, intraoperative blood loss and complications were recorded. The vertebral canal cross-sectional area, intervertebral foramen height, intervertebral space height, and lumbar lordosis angle were examined before and after surgery. Visual analogue scale scores for low back pain and leg pain were assessed before and after surgery. Oswestry disability index was used to assess lumbar function before and after surgery. Macnab criteria were used to evaluate the efficacy at the final follow-up after surgery. RESULTS AND CONCLUSION: (1) Operation time was 110-235 minutes, averagely 169.4 minutes. Intraoperative blood loss was 70-180 mL, averagely 112.4 mL. (2) After 3-8 months of follow-up, the visual analogue scale scores of low back pain and lower extremity pain 1 month after surgery and in final follow-up were significantly lower than those before operation (both P 0.05). (6) It is concluded that robot-assisted unilateral-decompression MIS-TLIF obtained satisfactory effect in bilateral lumbar canal stenosis patients presenting with unilateral symptoms.

SELECTION OF CITATIONS
SEARCH DETAIL